Linear Boiler Manuale Utente

Navigare online o scaricare Manuale Utente per no Linear Boiler. Linear Boiler User's Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 28
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
PAGE 1
BIASI B/40
LINEAR
6-12 SECTION
REV. H
Please Read Instructions Carefully
Save for Future Reference
Manufactured by:
Manufactured by:Manufactured by:
Manufactured by:
Biasi S.p.A.
Biasi S.p.A.Biasi S.p.A.
Biasi S.p.A.
Verona, Italy
Verona, ItalyVerona, Italy
Verona, Italy
Distributed By:
Distributed By:Distributed By:
Distributed By:
QHT
QHTQHT
QHT
QUINCY HYDRONIC TECH
QUINCY HYDRONIC TECHQUINCY HYDRONIC TECH
QUINCY HYDRONIC TECHNOLOGY
NOLOGYNOLOGY
NOLOGY, INC.
, INC., INC.
, INC.
3560 LAFAYETTE RD
3560 LAFAYETTE RD3560 LAFAYETTE RD
3560 LAFAYETTE RD
PORTSMOUTH, NH 0380
PORTSMOUTH, NH 0380PORTSMOUTH, NH 0380
PORTSMOUTH, NH 03801
11
1
PHONE: 603
PHONE: 603PHONE: 603
PHONE: 603-
--
-334
334334
334-
--
-6400
64006400
6400
FAX: 603
FAX: 603FAX: 603
FAX: 603-
--
-334
334334
334-
--
-6401
64016401
6401
Boiler Manual And Installation
Instructions for Atmospheric Venting
LINEAR
BOILER
If the information in this manual is not followed
exactly, a fire explosion may result causing property
damage, personal injury or loss of life.
WARNING
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance
• Do not touch any electric switch; do not use any
phone in your building
• Immediately call your gas supplier from another
location. Follow the gas supplier’s instructions.
• If you can not reach your gas supplier call the
fire department
DANGER
Vedere la pagina 0
1 2 3 4 5 6 ... 27 28

Sommario

Pagina 1 - 6-12 SECTION

PAGE 1 BIASI B/40 LINEAR 6-12 SECTION REV. H Please Read Instructions Carefully Save for Future Reference Manufactured by:Manufactured by:Manufactu

Pagina 2

BIASI B/40 PAGE 10 Good, reliable operation with a minimum of service starts with attention to the small details: 1. Setting the nozzle position a

Pagina 3 - TABLE OF CONTENTS

PAGE 11 BIASI B/40 BURNER MANUFACTURER Heat WiseBoiler Model B-406 B-407 B-408 B-409 B-410 B-411 B-412Burner ModelSU-3 SU-3 SU-4 SU-5 SU-5 SU-6 SU-6

Pagina 4

BIASI B/40 PAGE 12 To check for gas leaks, use a gas detector or apply a soap solution to the joints. DO NOT USE AN Direction of flow Manual Shutof

Pagina 5 - WARNING

PAGE 13 BIASI B/40 Piping should consist of: 1. A shut off valve approximately 6’ away from the unit. 2. A 1/8” plugged NPT tapping for gas pressu

Pagina 6 - 2. General Information:

BIASI B/40 PAGE 14 The B-40 Linear boiler is a high efficiency unit that requires proper venting. The boiler must be vented to the outdoors by mea

Pagina 7 - 5. Boiler Location:

PAGE 15 BIASI B/40 All piping must conform to state and local codes. The supply and return manifolds for B-40 Linear boilers are 2 1/2” male N

Pagina 9

PAGE 17 BIASI B/40 NOTE: All piping, boiler controls, gauges and valves must be installed before the jacket has been assembled on the boiler. Refe

Pagina 10 - 8. Burner Setup:

BIASI B/40 PAGE 18 1 2 3 4 5 6 7 8 9 1 On/Off Switch 2 Min. Boiler Temp. Thermostat 3 Max Boiler Temp. Thermostat 4 Thermostat By-Pass Button 5

Pagina 11

PAGE 19 BIASI B/40 1 2 3 4 5 6 7 8 9 1. On/Off Switch — Turns power to control panel on and off and will disable power to the burner assuming the

Pagina 12 - 9. Gas Line Piping

BIASI B/40 PAGE 2 Dear Customer: Thank you for buying a Linear commercial boiler. The Linear is a cast iron, oil or gas fired hot water boiler, us

Pagina 13 - BIASI B/40

BIASI B/40 PAGE 20 B-40 Control Panel Wiring Diagram for Beckett/Heat Wise Oil Burner 24V CIRCULATOR RELAYBURNER CONTROL

Pagina 14 - 10. Breeching and Venting:

PAGE 21 BIASI B/40 B-40 Control Panel Wiring Diagram for Beckett/Heat Wise Oil Burner Line Voltage CIRCULATOR RELAYBURNER CONTROL

Pagina 15 - 10. Blocked Flue Switch:

BIASI B/40 PAGE 22 B-40 Control Panel Wiring Diagram for Riello Oil Burner

Pagina 16 - PAGE 16

PAGE 23 BIASI B/40 B-40 Control Panel Wiring Diagram for Heat Wise Gas Burners CIRCULATOR RELAYBurner Primary Control

Pagina 17 - 12. Boiler Jacket Assembly:

BIASI B/40 PAGE 24 Check for fouling or soot buildup in the combustion chamber at least every twelve (12) months. Caution: Black carbon soot in

Pagina 18 - 13. Wiring:

PAGE 25 BIASI B/40 System Checkout: Boiler Model No._________________ Serial No.__________ Original Purchaser: Installer: ____________

Pagina 20 - BURNER CONTROL

PAGE 27 BIASI B/40

Pagina 21

BIASI B/40 PAGE 28 ITEM #: B40 REV. H Warranty For BIASI B40 Series Commercial Cast-Iron Water Boilers FIRST YEAR through TENTH YEAR-WARRANTY FOR B

Pagina 22 - PAGE 22

PAGE 3 BIASI B/40 BIASI B-40 Linear Series Section Page Important Information 1 4 General Informati

Pagina 23 - Burner Primary Control

BIASI B/40 PAGE 4 IMPORTANT INFORMATION Please read this page carefully. ALL BOILERS MUST BE INSTALLED IN ACCORDANCE WITH NATIONAL, STATE AND LOCAL

Pagina 24 - 15. Maintenance:

PAGE 5 BIASI B/40 Any appliance that burns natural gas, propane gas, fuel oil, wood or coal is capable of producing carbon monoxide (CO). Carbon Mo

Pagina 25 - 16. Installer Notes

BIASI B/40 PAGE 6 The Linear series are wet base design, sectional, cast-iron boilers for forced hot water heating systems. The Linear boilers are d

Pagina 26 - PAGE 26

PAGE 7 BIASI B/40 Locate the boiler to provide sufficient clearance for inspection, servicing and maintenance. Minimum clearance to construction or

Pagina 27 - PAGE 27

BIASI B/40 PAGE 8 All Linear series boilers are shipped either as an assembled boiler block or a knock-down boiler block. If the block came unasse

Pagina 28 - Warranty

PAGE 9 BIASI B/40 Figure 1:Diagram illustrating the location and function of the front and rear boiler tappings. Boiler Model Length (L) B-40/6 34

Commenti su questo manuale

Nessun commento